SALIENT FEATURES

  • 10.4” High Resolution Color TFT Display
  • Low power Consumption deisgn with stand by mode
  • Audibale and Visual alarm and adjustable Alarm Limits
  • Trend Data storage upto 360 Hrs
  • Humanized operational Interface
  • Streamlined Design with foldable handle
  • Suitable for Adult ,Peadiatric and neonatal patients
  • WAN communication function to central monitoring system
  • HL7 systems compatible
  • Display of OxyCRG and 7 Lead ECG wavefrom , Big font mode, User difinable Display format
  • Unique Electrosurgical interference filter design ensure no ECG, HR or SPO@ wont influenced
  • Goertzel arithmetic ensures fast and accurate NIBP readings
  • Nasal and RA-LL method of respiration monitoring ( user selectable )
  • Auto current drift balance systems ensures accurate RESP monitoring
  • Optional : Masimo Spo2 and Suntech NIBP


  • Technical Specifications

    ECG

  • Lead Mode : I,II,III,aVR,aVL,aVF,V
  • Gain,: 0.25,0.50,1,2
  • Sweep Speed: 6.25, 12.5,25,and 50 mm/sec
  • HR Range : 15~300 BPM
  • Calibration :+/-1mV
  • Accuracy +/- 3 BPM



  • SPO2

  • Display : Waveform and % Value
  • Measurement Range : 0~100%
  • Accuracy : 1%
  • PR Range : 15~300 BPM
  • Accuracy : +/-3BPM
  • Resolution : 1BPM


  • NIBP

  • Principle : Oscillometric
  • Measurement Type : Adult, Peadiatric, Neonatal
  • Measurement Method : Manual, Automatic, STAT
  • Unit: mmHg or kPa
  • Accuracy : +/-10mmHg or +/-5%

  • Temperature

  • Number of Channels : 2 channel
  • Measuremtn Range : 0~50 Degree
  • Resolution : 0.1 Degree
  • Display : T1,T2, Delta T
  • Unit: Degree or Farenheat Selectable



  • Respiration

  • Principle : RA-LL Impeadence
  • Measurement Range: 0~156BPM
  • Accuracy : +/-3 BPM
  • Resolution : 2BPM

  • EtCo2 (Plug and Play)

  • Measurement Types : Side Stream/Micro Stream/Main Stream
  • Measurement Range : 0~19.7% , 0~150 mmHg, 0~20kPa

  • Accuracy

  • 0~40 mmHg +/-2 mmHg or +/-2%
  • 41~70mmHg +/- 5%
  • 71~100 mmHg +/- 8%
  • 100~150 mmHg +/-10%



  • IBP

  • Measurement Range: -10~300 mmHg
  • Number of Channels: single or dual channels selectable
  • Accuracy: +/-2mmHg or +/-2%
  • Pressure Tag: ART.CVP, RVP, LAP, RAP, PAP, ICP, LVP